2004 / 97008 - H80J12
HIGH POWER PULSED MICROWAVE AMPLIFIER
- SPECIFICATIONS -
MODEL 2004/97008-H80J12
10-kilowatt, 8% Duty, 8.0 - 12.0 GHz
Dedicated Amplifier System, Series 2004
Series 2004 Amplifier Systems provide the latest in high power, low noise operation for high
performance instrumentation radar requirements. This state-of-the-art product delivers incomparable
pulsed RF performance with exceptional low phase noise for operation in benign laboratory
or hostile field environments.
Microprocessors provide the operator, and or computer, access to monitor TWT conditions,
fault latching, and control of power supply and modulator parameters. An RS-232 interface provides the
ability to remotely operate, monitor, control and adjust the system. The optional 10/100 Base Ethernet
provides the ability to remotely operate, monitor & control operation of the amplifier. Any fault condition
latches information. Software is provided to operate with MS Windows.
R F SPECIFICATIONS
OUTPUT PEAK POWER, SAT | :+70 dBm (minimum) |
DUTY CYCLE | :8 % (maximum) |
INPUT POWER (For rated output) | :0 dB (maximum) |
SPURIOUS OUTPUT | :10-250 Hz  :70 dBc (minimum) |
  | >250 Hz  :80 dBc(minimum) |
|
|
R F PULSE MODULATION SPECIFICATIONS
|
PULSE WIDTH, Note 1 | : 0.05 - 50.0 µs |
REPETITION RATE, Note 1 | : 0 to 120 kHz (maximum) |
RISE & FALL TIME, Note 1 & 2 | : 20 ns (maximum) |
DROOP, Note 2 | : 0.01 dB/µs (maximum) |
PULSE JITTER | : ± 2 ns (maximum) |
VIDEO / RF THROUGHPUT DELAY | : 300 ns (maximum) |
* NOTES: 1) Product of the Pulse Width and Pulse Repetition Rate is limited by Duty Cycle.
2) All RF Modulation Parameters are Measured at Maximum Peak Power Output, and are Dependent
Upon TWT Characteristics.
|
|
|
RF SAMPLING
|
FORWARD OUTPUT POWER SAMPLE | : - 50 dB |
REVERSE OUTPUT POWER SAMPLE | : - 40 dB |
TWT DRIVE POWER SAMPLE | : - 30 dB |
RF INPUT POWER SAMPLE | : - 10 dB |
|
|
ELECTRICAL
|
PRIMARY INPUT MAIN POWER | : 120-210 v, 60 Hz, Optional 210-250 v |
MODULATION INPUT PULSE | : +5v TTL |
|
|
CONDITIONS MONITORED VIA INTERFACE
Cathode Voltage: |
00.00 kV |
Cathode Current: |
000 mA |
Collector Voltage:
| 00.0 kV |
Collector Current: |
000 mA |
Heater Voltage: |
0.0 V |
Heater Current: |
0.0 A |
Grid Bias Voltage:
| 000 V |
Grid Pulse Amplitude: |
000 v |
Helix Current: |
00.00 mA |
Fan Speed: |
10 - 100% |
Pulse Received:
| Yes/No |
Access Interlock:
| Green / Red Fault Indicator |
Excessive Temperature: |
Green / Red Fault Indicator |
VSWR: |
Green / Red Fault Indicator |
|
|
|
|
|
CONNECTORS
|
R F Input | : Co-ax, Type "NF" |
R F Output | : Waveguide, WR-90 |
R F Output Samples | : Co-ax, Type "NF" |
Modulation Input Pulse | : Co-ax, Type "BNCF" |
Computer Interface | : RS232, DB-25 |
Primary Power Input | : HBL 2815, five wire |
|
|
MECHANICAL
|
ENCLOSURE DIMENSIONS | : 36.5"H x 23.5"W x 30"D |
WEIGHT | : 280 pounds (nominal) |
COOLING | : Self contained forced air |
|
|
ENVIRONMENTAL
|
TEMPERATURE: Operating Storage | : 0 to +50�C Derate 10�C for 10,000 foot Operation : - 30 to +60�C |
HUMIDITY | : 0 to 95% non-condensing |
ALTITUDE | : 0 to 10,000 feet above sea level |
|
|
ACCESSORIES SUPPLIED |
1-each, Instruction/Service Manual |
1-each, Primary Input Power Connector |
1-each, CD ROM, Computer Operating Software |
|
|
Specifications are subject to change and negotiation. |
|