HIGH POWER CW MICROWAVE AMPLIFIER
- SPECIFICATIONS -



MODEL 9820/95300-H80J12

200 WATT, CW, 8.0 - 12.0 GHz

Dedicated Amplifier System Series 9820



Series 9820 Amplifier Systems provide the maximum in reliability, cost effectiveness and convenience. This state-of-the-art product delivers high performance for benign laboratory or hostile field environments.

Microprocessors provide the operator, and or computer, access to monitor TWT conditions, fault latching, and control of the power supply for both the safety of the TWT and the operator. These controls also provide a TWT warm-up delay, automatic sequencing of High Voltage and Beam Current as well as an automatic recycle feature.



R F SPECIFICATIONS

OUTPUT POWER, RATED : +53 dBm (nominal)
GAIN : 45 dB (nominal)
DUTY CYCLE : 100 %, CW
INPUT POWER (for rated output)optional : 0 dBm
NOISE FIGURE : 22 dB (typical)
SPURIOUS OUTPUT     : 0-250 Hz
> 250 Hz
: -55 dBc
: -60 dBc
POWER RIPPLE : 0.1 dB (maximum)
LOAD V.S.W.R. : 2.5 : 1 (maximum)
GAIN STABILITY : 0.25 dB / 24 hours (typical) (Note 1)

* NOTE: 1) At constant drive and temperature after warm-up period.



MONITOR / TEST POINTS (OPTIONAL)

OUTPUT POWER SAMPLE(optional) : -30 dB (nominal)


ELECTRICAL

PRIMARY INPUT MAIN POWER : 240 VAC, 60 Hz, Single Phase


CONTROLS and INDICATORS

FRONT PANEL: Switches : POWER, OPERATE / RESET
ILLUMINATED STATUS MONITOR : POWER, TIMING, OPERATE, HELIX
  CURRENT, REMOTE
ILLUMINATED FAULT MONITORS : HIGH VSWR, LINE, INTLK, HELIX, TEMP
REMOTE MONITORING and CONTROL : RS-232
REMOTE CONTROL (option -P) : IEEE-488

FAULT and MONITORING

Via COMPUTER Cathode Voltage: 00.00 kV Cathode Current: 000 mA
  Collector Voltage: 00.0 kV Collector Current: 000 mA
  Heater Voltage: 0.0 V Heater Current: 0.0 A
  Grid Bias Voltage: 000 V Grid Pulse Amplitude: 000 v
  Helix Current: 00.00 mA VSWR: 000.0 %
  Interlock: Fault Temp: Fault

CONNECTORS
R F INPUT : Co-ax, Type "NF"
R F Output : Co-ax, Type "NF"
Primary Power Input : Connector, NEMA L6-20
Remote Control : DB-25


MECHANICAL
FRONT PANEL : Standard RETMA 3/16" thick,
  with slotted mounting holes.
DIMENSIONS: Front Panel
Depth
: Width 19", Height 8 1/4"
: Chassis, 26"
: Overall, 28"
FINISH: Front Panel
Chassis
: Enamel, Color White & Black
: Alodine, Color Silver
WEIGHT : 90 pounds (Nominal)
COOLING : Self contained forced air


ENVIRONMENTAL
TEMPERATURE: Operating
 Storage
: 0 to +50�C
: - 30 to +60�C
HUMIDITY : 0 to 95% non-condensing
ALTITUDE : 0 to 10,000 feet above sea level


OPTIONS
OPTIONS E - RACK MOUNTING
Allows the unit to be mounted in a standard EIA 19 inch rack cabinet, incorporating side mounted slides.
OPTION G - 400 Hz
Provides for 400 Hz AC frequency operation
OPTION J - OUTPUT ISOLATOR
Protects the TWT from varying load VSWR conditions. Insertion loss of the Isolator will lower the output power slightly (0.5 dB typically) from normal. Call the factory for configuration and dimensions. (Isolator may be provided externally)
OPTION X - REFLECTED POWER PROTECTION
Protects the TWT from high load VSWR and is intended for use on ultra wide band or high power units for which Isolators are not normally available. Consists of a coupler and detector that turns the TWTA off when excessive reflected power is sensed. Typical insertion loss is 0.5 dB.
ACCESSORIES SUPPLIED
1-each, Instruction/Service Manual
1-each, Primary Input Power Connector

Back         Top of Page